| PELCO - CM9760 CPU Redundancy |
|
|
| CM9760-SEU |
S28451 |
Serial expansion unit; supports switching of an additional 16 data ports. |
|
|
|
|
|
|
|
|
|
| CM9760-SAT-X |
S27309 |
Remote 16 x 4 Satellite switcher for CM9760 matrix |
|
|
|
|
|
|
|
|
|
| CM9700-CC1 |
S38634 |
CPU Controller complete |
|
|
|
|
|
|
|
|
|
| CM9760-HS |
S28417 |
CPU Changeover system for CM9760 & CM9740 |
|
|
|
|
Continuous Monitoring of Active and Standby CPUs
Automatic or Manual Switching to Standby CPU in the Event of a Failure
Diagnostic LEDs Show CPU Status
Audible Alert in Case of CPU Failure
Manual Control of Diagnostic Monitor and Keyboard Allows for Servicing/Programming of Either CPU Without Interrupting System Operation
Automatically Routes Data Lines for Keyboards, Bays, and Accessories to Standby CPU
Backward Compatible With Older Matrix Systems
Fits a 19-Inch Standard Rack |
|
|
|
|
|
| PELCO - CM9760 & CM9740 Alarm Interface Unit |
|
|
| CM9760-ALM |
S23707 |
Alarm I/F unit with 64 n/o or n/c inputs |
|
|
|
|
Up to 4 units can be chained together giving a total of 256 alarms,
accessed & supported from a single sercom port.
.
Note: Larger Inputs & Looping Inputs & Larger outputs for the Pelco CM9760 systems are available on application
To optimise the performance of the Pelco CM9760 System - we recommend setup by qualified personnel.
Please contact your Pacom office to obtain a quote for set up cost. |
|
|
|
|
|
| PELCO - CM9760 Relay Interface Unit |
|
|
| CM9760-REL |
S23909 |
CM9760 Relay Interface Unit |
|
|
|
|
Provides 64 single throw contact outputs for
operating different peripheral equipment
Each Unit Provides Up to 64 Single-Pole, Single-Throw (SPST) Contact
Outputs for Operating Different Peripheral Equipment
Relay Output Contacts Can Be Configured for Normally Open (Factory
Default) or Normally Closed Operation
Memory Feature Allows Relay Groups to Retain or Hold Their
Contact Position in the Event of a Power Failure or Front Panel Reset
Multiple Units Can Be Daisy-Chained to Extend the Number of Relay
Contact Outputs Controlled From a Single Port On the CC1 (Over
5,000 Relay Outputs Can Be Configured)
The Relay Unit Can Be Remotely Placed Up to 4,000 Feet (1,219 meters)
From the Controller (RS-422 Operation)
All of the above relay switching functions can be configured from the 2040/9760MGR setup files |
|
|
|
|
|
| PELCO - CM9760 & CM9740 Data Translator and High Level Interface |
|
|
| CM9760-DT-X |
S24861 |
CM9760 & CM9740 Data Translator and High Level Interface |
|
|
|
|
The Pelco CM9760-DT Data translator is a
protocol translation device that isolates whilst
interfacing the Pelco CM9760 with any device
capable of communication in ASCII.
The Data Translator will enable Building Management
& Security Systems to easily interface & control the Pelco CM9760. |
|
|
|
|
|
|
|
| CM9760-DT4-X |
S28512 |
Same as CM9760-DT-X except with RS422 output port |
|
|
|
|
|
|
|
| PELCO - CM9760 & CM9740 DMR Data Manager |
|
|
| CM9760-DMR-X |
S28289 |
CM9760 & CM9740 DMR Data Manager |
|
|
|
|
The Data manager provides you with a four to one
expansion of the number of data (sercom) ports available
on a CM9760 or CM9740 CPU. It can also be used on the same matrixes in the following 3 applications:
1. Expanding the number of cameras controlled through one port.
2. Expanding the number of keyboards connected to one port.
3. To interface up to 4 networked CPU’s to control a common group of cameras. |
|
|
|
|
|
| PELCO - CM9760 & CM9740 PTZ Coaxitron Code Translators |
|
|
| CM9760-CXT-A |
S25483 |
CM9760 & CM9740 PTZ Coaxitron Code Translators |
|
|
|
|
Coaxitron Translator for CM9760 with up to 16
Coaxitron capable receiver/drivers
Allow Coaxitron Control From Any RS-422 “P” or “D” Protocol Device
16 Looping Video Inputs Allow for Easy Connection Between Switch & Cameras.
Send PTZ Control Commands on a Camera’s Video Cable
Fits a Standard 19-Inch Rack Mount
230 VAC
44.5 H x 482.6 W x 270 D mm |
|
|
|
|
|